Investigation of Best Operating Conditions for Treatment of Oily Wastewters with Hollow Fiber Ultrafiltartion Membranes

Authors

  • Mohsen Abbasi Department of Chemical Engineering, School of Chemical and Petrolium Engineering, Persian Gulf University, Bushehr, 75169, Iran
  • Mohammad Reza Sebzari Department of Chemical Engineering, Lamerd Branch, Islamic Azad University, Lamerd, Iran

DOI:

https://doi.org/10.6000/1929-6037.2014.03.04.9

Keywords:

Taguchi method, ultrafiltration, Oily wastewater treatment.

Abstract

This paper investigates the optimum operating conditions for treatment of oily wastewaters by application of UF process using the Taguchi method. The following operating conditions have been considered in this investigation: Back Wash time; Trans-membrane pressure (TMP); Flow rate and temperature. The optimum operating conditions of UF were found as follows: Backwash time of 5 s; TMP of 2 bar; Flow rate of 12 L min-1 and temperature of 30 °C.

Experimental results presents that the importance level of the percentage contributions of each item is: (1) TMP (98.80 %), (2) back wash time (7.85 %), (3) flow rate (1.11 %), and (4) the feed temperature (0.819 %).

References

Hosein Abadi SR, Sebzari MR, Hemati M, Rekabdar F, Mohammadi T. Ceramic membrane performance. Desalination 2011; 265: 222-8. http://dx.doi.org/10.1016/j.desal.2010.07.055 DOI: https://doi.org/10.1016/j.desal.2010.07.055

Cui J, Zhang X, Liu H, Liu S, Yeung KL. Preparation. J Membr Sci 2008; 325: 420-6. http://dx.doi.org/10.1016/j.memsci.2008.08.015 DOI: https://doi.org/10.1016/j.memsci.2008.08.015

Hua FL, Tsang YF, Wang YJ, Chan SY, Chua H, Sin SN. Performance. Chem Eng J 2007; 128: 169-5. http://dx.doi.org/10.1016/j.cej.2006.10.017 DOI: https://doi.org/10.1016/j.cej.2006.10.017

Ebrahimi M, Willershausen D, Ashaghi KS, Engel L, Placido L, Mund P, Bolduan P, Czermak P. Investigations. Desalination 2010, 250: 991-6. http://dx.doi.org/10.1016/j.desal.2009.09.088 DOI: https://doi.org/10.1016/j.desal.2009.09.088

Mohamed YT, Hussin LMS, Gad HMH, Daifullah AAM, Abo-El-Enein SA. Membrane Stabilitiy. J Membr Sep Tecnol 2013; 2: 102-8. DOI: https://doi.org/10.6000/1929-6037.2013.02.01.10

Jie Y, Dandan Z, Chao C, Hongxia G, Bangjun H, Yahong H, Zhenao G, Shuren Y, Hong Y, Ziwei D, van Agtmaal S, Chunhui F. Pilot Scale. J Membr Sep Tecnol 2014; 3: 44-49. DOI: https://doi.org/10.6000/1929-6037.2014.03.01.4

Tong G, Song J, Wang P, Zhao H, Tan X. Preparation. J Membr Sep Tecnol 2014; 3: 146-53. DOI: https://doi.org/10.6000/1929-6037.2014.03.03.5

Wang SB, Pan C, Two-phase. Exp Thermal Fluid Sci 1998; 17: 189-201. http://dx.doi.org/10.1016/S0894-1777(98)00005-3 DOI: https://doi.org/10.1016/S0894-1777(98)00005-3

Wu DH, Chang MS. Use. Materials Science and Engineering 2004; 379: 366-71. http://dx.doi.org/10.1016/j.msea.2004.03.006 DOI: https://doi.org/10.1016/j.msea.2004.03.006

Chiang, KT. Optimization. Int Commun Heat Mass Transfer 2005; 32: 1193-201. http://dx.doi.org/10.1016/j.icheatmasstransfer.2005.05.015 DOI: https://doi.org/10.1016/j.icheatmasstransfer.2005.05.015

Erzurumlu T, Ozcelik B. Minimization. Mate Design 2006; 27: 853-61. http://dx.doi.org/10.1016/j.matdes.2005.03.017 DOI: https://doi.org/10.1016/j.matdes.2005.03.017

Wang TY, Huang CY. Improving. European J Operational Res 2007, 176: 1052-65. http://dx.doi.org/10.1016/j.ejor.2005.08.020 DOI: https://doi.org/10.1016/j.ejor.2005.08.020

Chou CS, Ho CY, Huang CI. The optimum conditions. Adv Powder Technol 2009; 20: 55-61. http://dx.doi.org/10.1016/j.apt.2008.02.002 DOI: https://doi.org/10.1016/j.apt.2008.02.002

Chou CS, Lin SH, Peng CC, Lu WC. The optimum conditions. Fuel Process Technol 2009; 90: 1041-46. http://dx.doi.org/10.1016/j.fuproc.2009.04.007 DOI: https://doi.org/10.1016/j.fuproc.2009.04.007

Chou CS, Yang RY, Chen JH, Chou SW, The optimum conditions for preparing. Powder Technol 2010; 199: 264-71. http://dx.doi.org/10.1016/j.powtec.2010.01.015 DOI: https://doi.org/10.1016/j.powtec.2010.01.015

Downloads

Published

2014-12-03

How to Cite

Abbasi, M., & Sebzari, M. R. (2014). Investigation of Best Operating Conditions for Treatment of Oily Wastewters with Hollow Fiber Ultrafiltartion Membranes. Journal of Membrane and Separation Technology, 3(4), 267–272. https://doi.org/10.6000/1929-6037.2014.03.04.9

Issue

Section

Articles