Separation Enhancement of Mechanical Filters by Adding Negative Air Ions
DOI:
https://doi.org/10.6000/1929-6037.2016.05.04.2Keywords:
Negative air ions, Filtration, Aerosol penetration, Mechanical filter.Abstract
The purpose of this work is to combine negative air ions (NAIs) and mechanical filters for removal of indoor suspended particulates. Various factors, including aerosol size (0.05-0.45 μm), face velocity (10 and 20 cm/s), species of aerosol (potassium chloride and dioctyl phthalate), relative humidity (30% and 70%), and concentrations of NAIs (2 ´ 104, 1 ´ 105, and 2 ´ 105 NAIs/cm3) were considered to evaluate their effects on the aerosol collection characteristics of filters. Results show that the aerosol penetration through the mechanical filter is higher than that through the mechanical filters cooperated with NAIs. This finding implies that the aerosol removal efficiency of mechanical filters can be improved by NAIs. Furthermore, the aerosol penetration through the mechanical filters increased with the aerosol size when NAIs were added. That is due to that the aerosol is easier to be charged when its size gets larger. The results also indicate the aerosol penetration decreased with the NAIs concentration increased. Reversely, aerosol penetration through the mechanical filters increased with the face velocity under the influence of NAIs. The aerosol penetration through the filter with NAIs was no affected with relative humidity. Finally, The penetration through the filter with NAIs against solid aerosol was lower than that against liquid aerosol.
References
Lance W. Indoor Particles: A Review. J Air Waste Manage Assoc 1996; 46: 98-126. https://doi.org/10.1080/10473289.1996.10467451 DOI: https://doi.org/10.1080/10473289.1996.10467451
Dockery DW, Pope CA, Xu X, Spengler JD, Ware JH, Martha EF, Ferris BG, Spezier FE. An association between air pollution and mortality in six U.S. cities. N Engl J Med 1993; 329(24): 1753-1759. https://doi.org/10.1056/NEJM199312093292401 DOI: https://doi.org/10.1056/NEJM199312093292401
Koenig JQ, Larson TV, Hamley QS, Rebolledo V, Dumler K, Checkoway H, Wang SZ, Lin D, Pierson WE. Pulmonary lung function in children associated with fine particulate matter. Environ Res 1993; 63(1): 26-38. https://doi.org/10.1006/enrs.1993.1123 DOI: https://doi.org/10.1006/enrs.1993.1123
Abbey DE, Burchette RJ, Knutsen SF, McDonnell WF, Lebowitz MD, Enright PL. Long-term particulate and other air pollutants and lung function in non-smokers. Am J Respir Crit Care Med 1998; 158(1): 289-298. https://doi.org/10.1164/ajrccm.158.1.9710101 DOI: https://doi.org/10.1164/ajrccm.158.1.9710101
Hind WC. Aerosol Technology. J. Wiley and Son: New York 1982.
Baumgartner HP, Löffler F. The Collection Performance of Electret Filters in the Particle Size Range of 10 nm-10 μm. J Aerosol Sci 1986; 17: 438-445. https://doi.org/10.1016/0021-8502(86)90126-6 DOI: https://doi.org/10.1016/0021-8502(86)90126-6
Lathrache R, Fissan HJ, Neumann S. Deposition of Submicron Particles on Electrically Charged Filters. J Aerosol Sci 1986; 17: 446-449. https://doi.org/10.1016/0021-8502(86)90127-8 DOI: https://doi.org/10.1016/0021-8502(86)90127-8
Fjeld RA, Owens TM. The Effect of Particle Charge on Penetration in the Electret Filter. IEEE Transactions on Industry Applications 1988; 24: 725-731. https://doi.org/10.1109/28.6128 DOI: https://doi.org/10.1109/28.6128
Chen CC, Huang SH. The Effects of particle Charge on the Performance of a Filtering Facepiece. Am Ind Hyg Assoc J 1998; 59: 227-233. https://doi.org/10.1080/15428119891010488 DOI: https://doi.org/10.1202/0002-8894(1998)059<0227:TEOPCO>2.0.CO;2
Pich J, Emi H, Kanaoka C. Coulombic Deposition Mechanism in Electret Filters. J Aerosol Sci 1987; 17: 29-35. https://doi.org/10.1016/0021-8502(87)90006-1 DOI: https://doi.org/10.1016/0021-8502(87)90006-1
Kanaoka C, Emi H, Otani Y, Iiyama T. Effect of Charging State of Particles on Electret Filtration. Aerosol Sci Tech 1987; 7: 1-13. https://doi.org/10.1080/02786828708959142 DOI: https://doi.org/10.1080/02786828708959142
Yang S, Lee WMG, Huang HL, Huang YC, Luo CH, Wu CC, Yu KU. Aerosol penetration properties of an electret filter with submicron aerosols with various operating factors. J Environ. Sci Health, Part A, Environ Sci Eng Toxic Hazard Substance Control 2007; 42(1): 1532-4117. DOI: https://doi.org/10.1080/10934520601015651
Luckner J, Wertejuk Z, Podgorski A. Effect of External Electrostatic Field on Filtration Efficiency of Fibrous Filters. Experimental Studies and Numerical Simulations. J Aerosol Sci 1994; 25: S195-S196. https://doi.org/10.1016/0021-8502(94)90328-X DOI: https://doi.org/10.1016/0021-8502(94)90328-X
Lee JK, Kim SC, Shin JH, Lee JE, Ku JH, Shin HS. Performance Evaluation of Electrostatically Augmented Air Filters Coupled with a Corona Precharger. Aerosol Sci Tech 2001; 35: 785-791. https://doi.org/10.1080/027868201753227334 DOI: https://doi.org/10.1080/027868201753227334
Mermelstein J, Kim S, Stioutas C. Electrostatically Enhanced Stainless Steel Filters: Effect of Filter Structure and Pore Size on Particle Removal. Aerosol Sci Tech 2002; 36: 62-75. https://doi.org/10.1080/027868202753339087 DOI: https://doi.org/10.1080/027868202753339087
Yang S, Lee GWM. Filtration Characteristics of a Fibrous Filter Pretreated with Anionic Surfactants for Monodisperse Solid Aerosols. J Aerosol Sci 2005; 36(4): 419–437. https://doi.org/10.1016/j.jaerosci.2004.10.002 DOI: https://doi.org/10.1016/j.jaerosci.2004.10.002
Agranovski IE, Huang Ruth, Pyankov OV, Altman IS, Grinshpun SA. Enhancement of the Performance of Low-Efficiency HVAC Filters Due to Continuous Unipolar Ion Emission. Aerosol Sci Tech 2006; 40(11): 963-968. https://doi.org/10.1080/02786820600833203 DOI: https://doi.org/10.1080/02786820600833203
Daniels SL. On the ionization of air for removal of noxious effluvia. IEEE Transactions on Plasma Science 2002; 30: 1471-1481. https://doi.org/10.1109/TPS.2002.804211 DOI: https://doi.org/10.1109/TPS.2002.804211
Grabarczyk Z. Effectiveness of indoor air cleaning with corona ionizers. Journal of Electrostatics 2001; 51-52: 278-283. https://doi.org/10.1016/S0304-3886(01)00058-4 DOI: https://doi.org/10.1016/S0304-3886(01)00058-4
Wu CC, Lee GWM. The temporal aerosol size distribution in indoor environment with negative electric discharge. J Aerosol Sci 2003; 34: S999-S1000.
Shi B, Ekberg L. Ionizer Assisted Air Filtration for Collection of Submicron and Ultrafine Particles Evaluation of Long-Term Performance and Influencing Factors. Environmental Science & Technology 2015; 49(11): 6891-6898. https://doi.org/10.1021/acs.est.5b00974 DOI: https://doi.org/10.1021/acs.est.5b00974
Lee DH, Jung JH, Lee BU. Effect of Treatment with a Natural Extract of Mukdenia Rossii (Oliv) Koidz and Unipolar Ion Emission on the Antibacterial Performance of Air Filters. Aerosol Air Qual Res 2013; 13: 771-776. https://doi.org/10.4209/aaqr.2012.08.0211 DOI: https://doi.org/10.4209/aaqr.2012.08.0211
Kim HJ, Han B, Kim YJ, Oda T, Won H. Submicrometer particle removal indoors by a novel electrostatic precipitator with high clean air delivery rate, low ozone emissions, and carbon fiber ionizer. Indoor Air 2013; 23(5): 369-378. https://doi.org/10.1111/ina.12037 DOI: https://doi.org/10.1111/ina.12037
Davies CN. Air Filtration. Academic Press: London 1973.
Ito T, Otani Y, Inomata H. Performance of air filters cleaned by supercritical carbon dioxide. Separation and Purification Technology 2004; 40: 41-46. https://doi.org/10.1016/j.seppur.2004.01.002 DOI: https://doi.org/10.1016/j.seppur.2004.01.002
Jasper W, Hinestroza J, Mohan A, Kim J, Shiels B, Gunay M, Thompson D, Barker R. Effect of xylene exposure on the performance of electret filter media. J Aerosol Sci 2006; 37: 903-911. https://doi.org/10.1016/j.jaerosci.2005.06.008 DOI: https://doi.org/10.1016/j.jaerosci.2005.06.008
ASHRAE. Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size. In ANSI/ASHRAE Standard 52.2-1999. American Society of Heating, Refrigerating, Air-conditioning Engineers, Inc, Atlanta 1999.
Jankowska E, Reponen HT, Willeke K, Grinshpuns SA, Choi KJ. Collection of fungal spores on air filters and spore reentrainment from filters into air. J Aerosol Sci 2000; 31: 969-978. https://doi.org/10.1016/S0021-8502(00)00017-3 DOI: https://doi.org/10.1016/S0021-8502(00)00017-3
White HJ. Particle Charging in Electrostatic Precipitation. Trans Am Inst Elect Engrs 1951; 70: 1186-1191. https://doi.org/10.1109/T-AIEE.1951.5060545 DOI: https://doi.org/10.1109/T-AIEE.1951.5060545
Liu BHY, Lee KW. Efficiency of membrane and Nuclepore filters for submicronmeter aerosols. Environ Sci Technol 1976; 76: 345-350. https://doi.org/10.1021/es60115a002 DOI: https://doi.org/10.1021/es60115a002
Downloads
Published
How to Cite
Issue
Section
License
Policy for Journals/Articles with Open Access
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are permitted and encouraged to post links to their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work
Policy for Journals / Manuscript with Paid Access
Authors who publish with this journal agree to the following terms:
- Publisher retain copyright .
- Authors are permitted and encouraged to post links to their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work .