Abstract

Solar Chimney Power Plants (SCPP) – also known as Solar Updraft Power Plants – consists in a structure composed by a glass collector, placed in a few meters from the ground, with a chimney in its center, in order to promote a pressure differential and consequently a heated air flow. On the bottom of the chimney, a turbine convert the kinetic energy from the heated airflow in electric power. Many mathematical and numerical methods for predict the performance of this kind of renewable energy plant have been conducted, but always with a divergence among them. The main objective of this work is to compare the mathematical methods of evaluation the overall performance, as well to propose a more accurate mathematical method, comparing all results with Manzanares Plant and other methods in the literature. Two approaches were studied and then modified: one based on continuity and momentum equation and the other based on the sum of all pressure drops along the system. The main reasons of the difference between the models analyzed are highlighted. The results shows that one of the proposed methods leads to a divergence of only 1.3% when compared to Manzanares pilot plant, i.e., with an excellent agreement with experimental data.

References


[1]Haaf W, Friederich K, MayrG, SchlaichJ.Solar Chimneys Part I: Principle and Construction of the Pilot Plant in Manzanares.International Journal of Solar Energy1983; 2(1):3-20.https://doi.org/10.1080/01425918308909911
[2]HaafW.Solar Chimneys.International Journal of Solar Energy1984; 2(2):141-161.https://doi.org/10.1080/01425918408909921
[3]KoonsrisukA, LorenteS, BejanA.Constructal solar chimney configuration.Int J Heat Mass Transf2010; 53(1-3):327-333.https://doi.org/10.1016/j.ijheatmasstransfer.2009.09.026
[4]StrobelC, MouraLM, MarianiVC.Radiative heat transfer considering the effect of multiple reflections in greenhouse structures.J Brazilian Soc Mech Sci Eng2016; 38(4).https://doi.org/10.1007/s40430-015-0466-6
[5]FathiN, AleyasinSS, VorobieffP.Numerical-analytical assessment on Manzanares prototype.ApplThermEng2016; 102:243-250.https://doi.org/10.1016/j.applthermaleng.2016.03.133
[6]GuoP, WangY, LiJ, WangY.Thermodynamic analysis of a solar chimney power plant system with soil heat storage.Appl Therm Eng2016; 100:1076-1084.https://doi.org/10.1016/j.applthermaleng.2016.03.008
[7]PadkiMM,SherifSA.On a simple analytical model for solar chimneys.IntJEnergy Res1999; 23(4):345-349.https://doi.org/10.1002/(SICI)1099-114X(19990325)23:4<345::AID-ER485>3.0.CO;2-Z
[8]Al-kayiemHH, ChikereO.Historic and recent progress in solar chimney power plant enhancing technologies.Renew Sustain Energy Rev2016; 58:1269-1292.https://doi.org/10.1016/j.rser.2015.12.331
[9]BernardesMAS, Von BackströmTW, KrögerDG.Analysis of some available heat transfer coefficients applicable to solar chimney power plant collectors.Sol Energy2009; 83(2):264-275.https://doi.org/10.1016/j.solener.2008.07.019
[10]BernardesMA, VoßA, WeinrebeG.Thermal and technical analyses of solar chimneys. Sol Energy2003; 75(6):511-524.https://doi.org/10.1016/j.solener.2003.09.012
[11]von BackströmTW, KirsteinCF, PillayLA.The influence of some secondary effects on solar chimney power plant performance.R D J2006; 1(22):5-10.
[12]WeinrebeG.Personal letter to author. Stuttgart,Germany, 2010; pp. 1-1.
[13]SiegelR,HowellJR.Thermal Radiation Heat Transfer,2002;1.
[14]BirdRB, StewartWE, LightfootEN.Transport Phenomena, 2nd ed. Wiley, 2007.
[15]StrobelC, MouraLM, MarianiVC.Improved model for solarchimney analysis,in ENCIT Brazilian Congress of Thermal Sciences and Engineering, 2012

Downloads

Published

2018-08-30

How to Cite

Strobel, C., Moura, L., & Mariani, V. (2018). Mathematical Methods for Solar Chimney Analysis. Journal of Technology Innovations in Renewable Energy, 7, 19–26. https://doi.org/10.6000/1929-6002.2018.07.03

Issue

Section

Articles